• Please read all the instructions and follow them carefully!
• Do not use Octanate LV after expiry date given on the label.
• During the procedure described below, sterility must be maintained!
• Reconstituted medicinal product should be inspected visually for particulate matter and discoloration prior to administration.
• The solution should be clear or slightly opalescent. Do not use solutions that are cloudy or have deposits.
• Use the prepared solution immediately, to prevent microbial contamination.
• Only use the infusion set provided. The use of other injection/infusion equipment can cause additional risks and treatment failure.
Instructions for preparing the solution:
1. Do not use the product directly from the refrigerator. Allow the solvent and the powder in the closed vials to reach room temperature.
2. Remove the flip off caps from both vials and clean the rubber stoppers with one of the provided alcohol swabs.
3. The transfer set is depicted in Fig. 1. Place the solvent vial on an even surface and hold it firmly. Take the transfer set and turn it upside down. Place the blue part of the transfer set on top of the solvent vial and press firmly down until it snaps (Fig. 2+3). Do not twist while attaching.

| 4. Place the powder vial on an even surface and hold it firmly. Take the solvent vial with the attached transfer set and turn it upside down. Place the white part on top of the powder vial and press firmly down until it snaps (Fig. 4). Do not twist while attaching. The solvent flows automatically into the powder vial. |  |
| 5. With both vials still attached, gently swirl the powder vial until the product is dissolved. The dissolving is completed in less than 10 minutes at room temperature. Slight foaming might occur during preparation. Unscrew the transfer set into two parts (Fig. 5). Foaming will disappear. Dispose the empty solvent vial with the blue part of the transfer set. |  |
Instructions for injection:
As a precaution, your pulse rate should be taken before and during the injection. If a marked increase in your pulse rate occurs, reduce the injection speed or interrupt the administration for a short time.
1. Attach the syringe to the white part of the transfer set. Turn the vial upside down and draw the solution into the syringe (Fig. 6).
The solution should be clear or slightly opalescent.
Once the solution has been transferred, firmly hold the plunger of the syringe (keeping it facing down) and remove the syringe from the transfer set (Fig. 7).
Dispose the empty vial together with the white part of the transfer set.

2. Clean the chosen injection site with one of the provided alcohol swabs.
3. Attach the provided infusion set to the syringe
4. Insert the injection needle into the chosen vein. If you have used a tourniquet to make the vein easier to see, this tourniquet should be released before you start injecting Octanate LV.
5. No blood must flow into the syringe due to the risk of formation of fibrin clots.
6. Inject the solution into the vein at a slow speed, not faster than 2-3 ml per minute.
If you use more than one vial of Octanate LV powder for one treatment, you may use the same injection needle and syringe again. The transfer set is for single use only.
Any unused product or waste material should be disposed of in accordance with local requirements.