The solvent of NovoSeven is provided in either a vial or in a pre-filled syringe. Not all presentations may be marketed. Handling procedures for both presentations are described below.
Powder in vial and solvent in vial:
Always use an aseptic technique.
Reconstitution
• NovoSeven powder and solvent vials should be at room temperature at reconstitution. Remove the plastic caps from the two vials. If the caps are loose or missing, do not use the vials. Clean the rubber stoppers on the vials with alcohol swabs and allow them to dry before use. Use a disposable syringe of an appropriate size and a vial adapter, transfer needle (20 – 26G) or other suitable device. If devices other than those supplied by Novo Nordisk are used, ensure the use of an adequate filter with a pore size of 25 micrometer.
• Attach the vial adapter to the solvent vial. If using a transfer needle, screw the transfer needle tightly onto the syringe.
• Pull the plunger to draw in a volume of air that is equal to the amount of solvent in the solvent vial (ml equals cc on the syringe).
• Screw the syringe tightly onto the vial adapter on the solvent vial. If using a transfer needle, insert the transfer needle into the rubber stopper of the solvent vial. Inject air into the vial by pushing the plunger until you feel a clear resistance.
• Hold the syringe with the solvent vial upside down. If using a transfer needle, make sure the transfer needle tip is in the solvent. Pull the plunger to draw the solvent into the syringe.
• Remove the empty solvent vial. If using a vial adapter, tip the syringe to remove it from the vial.
• Attach the syringe with the vial adapter or transfer needle to the powder vial. If using a transfer needle, make sure to penetrate the centre of the rubber stopper. Hold the syringe slightly tilted with the vial facing downwards. Push the plunger slowly to inject the solvent into the powder vial. Make sure not to aim the stream of solvent directly at the NovoSeven powder as this will cause foaming.
• Gently swirl the vial until all the powder is dissolved. Do not shake the vial as this will cause foaming.
NovoSeven reconstituted solution is colourless and should be inspected visually for particulate matter and discolouration prior to administration.
Do not store reconstituted NovoSeven in plastic syringes, unless as described in section 6.3.
It is recommended to use NovoSeven immediately after reconstitution, unless as described in section 6.3.
Administration
• Ensure that the plunger is pushed all the way in before turning the syringe upside down (it may have been pushed out by the pressure in the syringe). If using a transfer needle, make sure the transfer needle tip is in the solution. Hold the syringe with the vial upside down and pull the plunger to draw all the solution into the syringe.
• If using a vial adapter, unscrew the vial adapter with the empty vial. If using a transfer needle, remove the transfer needle from the vial, replace the transfer needle cap, and twist the transfer needle off the syringe.
• NovoSeven is now ready for injection. Locate a suitable site, and slowly inject NovoSeven into a vein over a period of 2 – 5 minutes without removing the needle from the injection site.
Safely dispose of the syringe, vials and any unused product. Any unused medicinal product or waste material should be disposed of in accordance with local requirements.
Powder in vial and solvent in pre-filled syringe:
Always use an aseptic technique.
Reconstitution
• The NovoSeven powder vial and pre-filled syringe with solvent should be at room temperature at reconstitution. Remove the plastic cap from the vial. If the cap is loose or missing, do not use the vial. Wipe the rubber stopper on the vial with a sterile alcohol swab and allow it to dry for a few seconds before use. Do not touch the rubber stopper after wiping it.
• Remove the protective paper from the vial adapter. Do not take the vial adapter out of the protective cap. If the protective paper is not fully sealed or it is broken do not use the vial adapter. Turn over the protective cap, and snap the vial adapter onto the vial. Lightly squeeze the protective cap with the thumb and index finger. Remove the protective cap from the vial adapter.
• Screw the plunger rod clockwise into the plunger inside the pre-filled syringe until resistance is felt. Remove the syringe cap from the pre-filled syringe by bending it down until the perforation breaks. Do not touch the syringe tip under the syringe cap. If the syringe cap is loose or missing, do not use the pre-filled syringe.
• Screw the pre-filled syringe securely onto the vial adapter until resistance is felt. Hold the pre-filled syringe slightly tilted with the vial pointing downwards. Push the plunger rod to inject all the solvent into the vial. Keep the plunger rod pressed down and swirl the vial gently until all the powder is dissolved. Do not shake the vial as this will cause foaming.
If a larger dose is needed, repeat the procedure with additional vials, pre-filled syringes and vial adapters.
The NovoSeven reconstituted solution is colourless and should be inspected visually for particulate matter and discolouration prior to administration.
It is recommended to use NovoSeven immediately after reconstitution. For storage conditions of the reconstituted medicinal product, see section 6.3.
Administration
• Keep the plunger rod pushed completely in. Turn the syringe with the vial upside down. Stop pushing the plunger rod and let it move back on its own while the reconstituted solution fills the syringe. Pull the plunger rod slightly downwards to draw the mixed solution into the syringe.
• While holding the vial upside down, tap the syringe gently to let any air bubbles rise to the top. Push the plunger rod slowly until all air bubbles are gone.
If the entire dose is not required, use the scale on the syringe to see how much mixed solution is withdrawn.
• Unscrew the vial adapter with the vial.
• NovoSeven is now ready for injection. Locate a suitable site, and slowly inject NovoSeven into a vein over a period of 2 – 5 minutes without removing the needle from the injection site.
Safely dispose of the used materials. Any unused medicinal product or waste material should be disposed of in accordance with local requirements.
Procedure for pooling of vials for hospital use only:
During in vitro studies, the chemical and physical in-use stability has been demonstrated for 24 hours at 25°C in a 50 ml syringe (polypropylene). Compatibility with the product was demonstrated for the system consisting of a 50 ml syringe (polypropylene), a 2 m infusion tube (polyethylene) and in-line filters within the range of 0.2 to 5 micrometer pore size.
Pooling of vials (hospital use only):
• All steps should be completed under controlled and validated aseptic conditions by adequately trained staff.
• If not reconstituted, pooled or used as recommended the in-use times and conditions prior to use are the responsibility of the user.
• Ensure that a vial adapter is used irrespective of presentation.
• Reconstitute the product as described above under Reconstitution for relevant product presentation. Unscrew the empty syringe from the vial adapter and for both presentations ensure that a vial adapter is attached to the vial containing reconstituted product.
• Repeat the procedure with the appropriate number of additional vials, solvent vials/pre-filled syringes and vial adapters.
• Draw approximately 5 ml of sterile air into the 50 ml syringe (polypropylene). Screw the syringe securely onto the vial adapter until resistance is felt. Hold the syringe slightly tilted with the vial pointing downwards. Push the plunger rod gently to inject a little air into the vial. Turn the syringe with the vial upside down and withdraw the contents of the vial into the syringe.
• Repeat the above procedure with the remaining vials with reconstituted product, to obtain the desired volume in the syringe.
• An in-line filter within the range of 0.2 to 5 micrometer pore size must be ensured for administration. Ensure that the syringe, the infusion tube and the in-line filter are primed and free of air before administration.
• The syringe with adequately reconstituted product is now ready for administration in a CE-marked infusion pump (accepting a 50 ml syringe).
• The infusion pump must only be operated by trained hospital personnel.