Renal disease
To ensure the safe use of PENTHROX as an analgesic the following precautions should be observed.
- Use the lowest effective dose to control pain
- Use with caution in the elderly or other patients with known risk factors for renal disease.
- Use with caution in patients diagnosed with clinical conditions which may pre-dispose to renal injury.
Methoxyflurane causes significant nephrotoxicity at high doses. Nephrotoxicity is thought to be associated with inorganic fluoride ions, a metabolic breakdown product. When administered as instructed for the analgesic indication, a single dose of 3 ml methoxyflurane produces serum levels of inorganic fluoride ions below 10 micromol/l. In the past when used as an anaesthetic agent, methoxyflurane at high doses caused significant nephrotoxicity, which was determined to occur at serum levels of inorganic fluoride ions greater than 40 micromol/l. Nephrotoxicity is also related to the rate of metabolism. Therefore factors that increase the rate of metabolism such as drugs that induce hepatic enzymes can increase the risk of toxicity with methoxyflurane as well as sub-groups of people with genetic variations that may result in fast metaboliser status (see section 4.5).
Liver disease
Methoxyflurane is metabolised in the liver, therefore increased exposures in patients with hepatic impairment can cause toxicity. PENTHROX must not be used in patients who have a history of showing signs of liver damage after previous methoxyflurane use or halogenated hydrocarbon anaesthesia (see section 4.3). PENTHROX should be used with care in patients with underlying hepatic conditions or with risks for hepatic dysfunction (such as enzyme inducers - see also section 4.5).
It has been reported that previous exposure to halogenated hydrocarbon anaesthetics (including methoxyflurane when used in the past as an anaesthetic agent), especially if the interval is less than 3 months, may increase the potential for hepatic injury.
Cautious clinical judgement should be exercised when PENTHROX is to be used more frequently than on one occasion every 3 months.
Cardiovascular system depression / use in elderly
Potential effects on blood pressure and heart rate are known class-effects of high dose methoxyflurane used in anaesthesia and other anaesthetics. They do not appear to be significant at the analgesic doses. There is no particular pattern to the patients' systolic blood pressure levels after methoxyflurane administration as an analgesic across age groups. However, as the risk may potentially be increased for older people with hypotension and bradycardia, caution should be exercised in the elderly due to possible reduction in blood pressure.
Central nervous system (CNS) effects
Secondary pharmacodynamic effects including potential CNS effects such as sedation, euphoria, amnesia, ability to concentrate, altered sensorimotor co-ordination and change in mood are also known class-effects. Self-administration of methoxyflurane in analgesic doses will be limited by occurrence of CNS effects, such as sedation. Whilst the possibility of CNS effects may be seen as risk factor for potential abuse, reports are very rare in post marketing use.
Respiratory depression
Respiratory depression has been reported also from analgesic doses (section 4.8). Respiration should be monitored due to the risk for respiratory depression and hypoxia.
Frequent repeated use
Due to the limitations on the dose of PENTHROX (refer to section 4.2) and the duration of pain relief, PENTHROX is not appropriate for providing relief of break-through pain/exacerbations in chronic pain conditions. PENTHROX is also not appropriate for relief of trauma related pain in closely repeated episodes for the same patient.
Butylated hydroxytoluene
PENTHROX contains the excipient, butylated hydroxytoluene (E321), a stabiliser. Butylated hydroxytoluene may cause local skin reactions (e.g. contact dermatitis), or irritation to the eyes and mucous membranes. See section 6.1.
Occupational exposure
Healthcare professionals who are regularly exposed to patients using PENTHROX inhalers should be aware of any relevant occupational health and safety guidelines for the use of inhalational agents. To reduce occupational exposure to methoxyflurane, the PENTHROX inhaler should always be used with the Activated Carbon (AC) Chamber which adsorbs exhaled methoxyflurane. Multiple use of PENTHROX Inhaler without the AC Chamber creates additional risk. Elevation of liver enzymes, blood urea nitrogen and serum uric acid have been reported in exposed maternity ward staff in delivery wards when methoxyflurane was used in the past in obstetric patients at the time of labour and delivery.
There have been reports of non-serious and transient reactions such as dizziness, headache, nausea or malaise, and reports of hypersensitivity reactions to methoxyflurane or other ingredients in healthcare professionals exposed to Penthrox. Measurements of exposure levels to methoxyflurane in hospital staff showed levels significantly lower than those associated with nephrotoxicity.